Technical Data | ||||
Type | 311 WH | 321 TA | 332 TE | 331 KL |
Version | With wall bracket | Rear mounting flange | Front mounting flange | With U bracket |
Nominal size | Ø 80 or 100 mm | |||
Display ranges according to EN 13190 | 0...100 °C | |||
0...120 °C | ||||
0...160 °C | ||||
0...250 °C | ||||
50...650 °C | ||||
Accuracy according to EN 13190 | Class 1 | |||
Medium / Application area | Liquid and gaseous media | |||
Immersion tube connection | Bottom | Central back | ||
Immersion tube diameter | Ø 12 mm | |||
Immersion tube length | Between 100...400 mm | |||
Capillary line | with Stainless steel-spiral protection, 1...15 m Length | |||
Process connection | Connection types: A, AK | |||
Nominal pressure | Max. 25 bar | |||
Measuring system | Nitrogen filled | |||
Degree of protection according to EN 60529 | IP65 | |||
Medium temperature | See selected display range | |||
Ambient temperature | -20…60 °C (only indoors) | |||
Storage temperature | -40…60 °C | |||
Nominal service temperature (EN 13190) | 23 °C ±2 °C | |||
Approvals | DNV | |||
Material | ||||
Not in contact with media | ||||
Housing | Crimped-on ring, Stainless
steel 1.4301, filled with silicone oil | |||
Window | Instrument glass | |||
Pointer movement | German silver / brass | |||
Dial | Aluminium white with black scale markings | |||
Aluminium silver with black scale markings (Display range 50...650 °C) | ||||
Pointer | Aluminium black | |||
Capillary line | Stainless steel 1.4571 | |||
In contact with media | ||||
Process connection | Stainless steel 1.4571 | |||
Immersion tube | Stainless steel 1.4572 |